Type | Volumetric Infusion Pump |
---|---|
Accuracy | ±5% |
KVO Rate | 1 mL/hr |
Delivery Rate Range | 0.1 to 999 mL/hr |
VTBI Range | 0.1 to 9999 mL |
Product code 2M8064.
Risks, repair by authorized personnel, use of Baxter parts, battery precautions.
Warnings and cautions related to personal safety are summarized in this section.
Describes front panel controls and indicators for Pump 1 and Pump 2.
Brief descriptions of built-in safety features and alarm conditions.
Lists various alerts, their associated LEDs, flow status, and possible causes.
Specific errors represented by two-digit codes, stored in memory for troubleshooting.
Ten automatic test modes for troubleshooting and manufacturing.
Addresses symptoms related to LCD, backlight, LEDs, and audible alarms.
Addresses occlusion alarms, panel lock, door open alarms, and pump noise.
Addresses safety clamp, free flow, and slide clamp issues.
Addresses INSERT SLIDECLAMP and AIR alarm issues.
Addresses accuracy issues and problems with front panel keys and audible tones.
Procedures for removing and installing the upstream occlusion sensor.
Procedures for removing and installing the downstream occlusion sensor.
Steps for replacing the air sensor assembly.
Steps for removing and replacing the CPU board.
Procedures for removing and replacing the display board.
Steps to verify various DC voltages and signals without pump disassembly.
Procedure to adjust VR2 to set the output current limit.
Procedure to adjust VR1 for the output current limit.
Procedure to mechanically calibrate the safety slide clamp.
Steps for calibrating the air sensor, including tubing modifications.
Procedure to calibrate the downstream occlusion sensor.
Steps for calibrating the upstream occlusion sensor.
Procedure to calibrate the slide clamp sensor.
Checks upstream/downstream occlusion sensors and DC voltages.
Checks air sensor and tube misloading sensor outputs.
Steps to run the pump's self-test and verify indications.
Verifies the door open alarm functionality and volume control.
Verifies the proper functioning of the slide clamp mechanism.
Verifies that no more than 0.5 mL of fluid flows in 60 seconds.
Tests the pump's ability to detect air bubbles of specified volumes.
Checks Force Sensing Resistor (FSR) values under different conditions.
Ensures proper operation of the downstream occlusion sensor.
Ensures proper performance of the upstream occlusion sensor.
Outlines tests for pump accuracy, including one-hour test.
Tests pump accuracy by measuring volume delivered over one hour.
Describes the ultrasonic principle of air detection.
Introduces the downstream and upstream occlusion sensors.
Details the switching-type DC power supply and its features.