Introduction to CFX Manager Software
16
Create a new Experiment (page 21). Set up the protocol and plate to begin a new
experiment.
NOTE: Select the appropriate instrument in the pull down list to make sure the
default plate settings match the instrument to be used for the experiment.
Repeat an Experiment. Set up an experiment with the protocol and plate from a
completed run. If needed, you can edit the experiment before the run
Open a Data File (page 69). Open a data file to analyze results
Open a Gene Study (page 101). Open a multi-file gene expression study to analyze
results from multiple gene expression experiments
Open User Preferences (page 121). Open the User Preferences window to customize
software settings
Detected Instruments Pane
CFX Manager software runs these 1000-series instruments:
CFX96 and CFX384 real-time PCR systems. Systems include a C1000 thermal cycler
and an optical reaction module
C1000 thermal cycler. The most versatile of the instruments run by CFX Manager
software. Add and remove these PCR reaction modules to the C1000 chassis in
seconds:
96-well fast reaction module, gradient enabled
384-well reaction module
Dual 48/48 fast reaction module, gradient enabled
S1000 thermal cycler connected to a C1000 thermal cycler. For more information,
see S1000 and C1000 thermal cycler instruction manuals
TIP: Locate PDF copies of the instruction manuals by opening the Documents
folder on the CFX Manager software installation CD.
You can simultaneously run up to four instruments with CFX Manager software, including a
combination of CFX96 system and CFX384 systems, or a mix of real-time PCR systems and
thermal cyclers.
Viewing Detected Instruments
Connected instruments appear in the Detected Instruments pane (page 17). This list shows
each instrument as an icon named with the serial number (default). The list of instruments also
shows individual blocks (Block A and Block B) for each dual block reaction module.
TIP: Right-click any instrument in the Detected Instruments pane to open the
Instrument Properties window and rename the instrument.
Figure 18 shows four detected instruments:
One C1000 thermal cycler (C48FSIM00) with a dual 48/48 reaction module
One S1000 thermal cycler (S96FSIM01) with a 96-well block, which is connected to
the C1000 thermal cycler called C48FSIM00
One CFX384 system (CFX384SIM03)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BIO RAD CFX96 and is the answer not in the manual?

BIO RAD CFX96 Specifications

General IconGeneral
Temperature Uniformity±0.4 °C
SoftwareCFX Maestro Software
Detection MethodReal-time PCR (qPCR)
Sample Capacity96-well plate
Excitation SourceLED
Ramp RateUp to 5°C/sec
Heating Rate5°C/sec
SensitivitySingle copy detection
Power Requirements100-240 V, 50/60 Hz
Temperature Range0–100 °C