4
10 Timing Test Commands 36
10.1 TIMing[:STATe] 36
10.2 TIMing:LOAD:SETTing 36
10.3 TIMing:LOAD:MODE 36
10.4 TIM:LOAD:SETT OFF 37
10.5 TIMing:LOAD:VALue 37
10.6 TIMing:TSTart:SOURce 37
10.7 TIMing:TSTart:EDGE 37
10.8 TIMing:TSTart:LEVel 38
10.9 TIMing:TEND:SOURce 38
10.10 TIMing:TEND:EDGE 38
10.11 TIMing:TEND:LEVel 38
10.12 TIMing:RESult 39
11 Frame Interface Command Introduction 40
11.1 Frame Format 40
12 Frame Commands 43
12.1 20H Set control mode 43
12.2 Set the input on/o state (21H) 43
12.3 Set/Read max input voltag. (22H/23H) 43
12.4 Set/Read the max input current. (24H/25H) 44
12.5 Set/Read max input power (26H/27H) 44
12.6 Select/Read operation mode (CC/CV/CW/CR) of electronic load. (28H/29H) 44
12.7 Set/Read current value of CC mod. (2AH/2BH) 45
12.8 8. Set/Read voltage value of CV mode. 2CH/2DH 45
12.9 9. Set/Read watt value of CW mode 2EH/2FH 45
12.10 10. Set/Read resistance value CR mode (30H/31H) 46
12.11 Set/Read CC mode transient current and timer parameter. (32H/33H) 46
12.12 Set/Read CV transient voltage and timer parameter. (34H/35H) 47
12.13 Set/Read CW transient watt and timer paramete. (36H/37H) 47
12.14 Set/Read CR transient resistance and timer paramete. (38H/39H) 47
12.15 Set /Read the list operation mode (CC) 3AH/3BH 48
12.16 Set/Read the list repeat mode. (3CH/3DH) 48
12.17 Set/Read list step counts. (3EH/3FH) 48
12.18 Set/Read one of the step’s current and time values. (40H/41H) 48
12.19 Save/Recall list le in appointed area.. (4CH/4DH) 49
12.20 Setting/Reading timer value of FOR LOAD ON (50H/51H 49
12.21 Disable/Enable timer of FOR LOAD ON (52H); Read timer state of FOR LOAD ON (53H) 49
12.22 Set communication address (54H) 49
12.23 Enable/Disable LOCAL control mode. (55H) 50
12.24 Enable/Disable remote sense mode. (56H/57H) 50
12.25 Set/Read trigger source. (58H/59H) 50
12.26 Send a trigger signal to trigging the electronic load. (5AH) 50
12.27 Saving/Recall user’s setting value in appointed memory area for recall. 50
12.28 Selecting/Reading FIXED/SHORT/TRAN/LIST/ BATTERY function mode. (5DH/5EH) 51
12.29 Read input voltage, current, power and relative state. (5FH) 51
12.30 Operation status register 51
12.31 Read status register 52
12.32 Read the information of E-Load (rated max current, max voltage, min voltage, max power, max
resistance, min resistance). (01H) 52
12.33 Set/Read hardware OPP value (02H/03H) 52
12.34 Set/Read OCP value. (80H/81H) 53
12.35 Set/Read OCP delay time. (82H/83H) 53
12.36 Enable/Disable OCP function. (84H/85H) 53