EasyManua.ls Logo

BK Precision XLN3640 - SCPI Command Subsystem

BK Precision XLN3640
207 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
73
*CLS
4.5.2 SCPI Command subsystem
ABORt
Abort the Output Action
FETCh Fetch Subsystem
:CURRent? Return the fetched output current
:VOLTage? Return the fetched output voltage
MEASure Measure subsystem
:CURRent? Return the measured output current
:VOLTage? Return the measured output voltage
MEMory Memory Subsystem
<NR1 | ? > select or return memory number, range
from 0 – 9
:VSET <NRf | ? > set or return voltage
:ISET <NRf | ? > set or return current
:SAVE store memory subsystem parameters
OUTput Output Subsystem
<Boolean > enable or disable output action
? return output state
:LIMit
:V
OLTage <NRf | ? > set or return voltage limit value
:CURRent <NRf | ? > set or return current limit value
:SR
:V
OLTage <NRf | ? > set or return voltage slew rate value
:CURRent <NRf | ? > set or return current slew rate value
:STATe? Return output mode (CV or CC)

Table of Contents