63
*CLS
6.5.2 SCPI Command subsystem
ABORt
Abort the Output Action
FETCh Fetch Subsystem
:CURRent? Return the fetched output current
:VOLTage? Return the fetched output voltage
MEASure Measure subsystem
:CURRent? Return the measured output current
:VOLTage? Return the measured output voltage
MEMory Memory Subsystem
<NR1 | ? > select or return memory number, range
from 0 - 9
:VSET <NRf | ? > set or return voltage:0-36V/0-60V
:ISET <NRf | ? > set or return current:0-40A/0-24A
:SAVE store memory subsystem parameters
OUTput Output Subsystem
<Boolean > enable or disable output action
? return output state
:LIMit
:VOLTage <NRf | ? > set or return voltage limit value
:CURRent <NRf | ? > set or return current limit value
:STATe? Return output mode (CV or CC)
:PROTection
:CLEar Reset latched protection
PROGram Program Subsystem
<NR1 | ? > select or return memory number, range

Table of Contents