5. Protection and Error Messages
5.1 Over-voltage Protection (OVP)
When the OVP is activated and voltage measured exceeds the setting point of
protected voltage, the system will enter the “Over Voltage Protect” mode that
will shut off the output and show OVP on the display. Press to reset
the protection mode and deactivate the buzzer.
=
36
.
.
=
.
4
0
.
FF
5.2 Over-current Protection (OCP)
When the OCP is activated and current measured exceeds the setting point of
protected current, system will enter the “Over Current Protect” mode that will
shut off the output and show OCP on the display. Press
to reset the
protection mode and deactivate buzzer.
.
63
=
.
1
0
.=
.
FF
5.3 Overpower Protection (OPP)
When the OPP is activated and power measured exceeds the setting point of
protected power, system will enter the “Over Power Protect” mode that will
shut off the output and display OPP on the screen. Press to reset the
protection mode and deactivate buzzer.
.
63
=
.
1
0
.=
.
FF