93
Return
String:
CV
Format:
CV or CC
4.7.3 Synchronous Control Commands
This set of commands can be used to control all the power supplies
connected in the RS-485 chain at once. Note that these commands will
not return an ā€œOKā€ string upon making a configuration.
C
ommand Description
==================================================
GRST Reset command. Brings the power supply to a
known state
GCLS Clear status
GCLR Clear protect
GPV Sets the output voltage value in Volts
GPC Sets the output current value in Amperes
GOUT Turns the output to ON or OFF
GOV Sets the OVP level
GOVP Sets the OVP on/off
GOC Sets the OCP level
GOCP Sets the OCP on/off
GOP Sets the OPP level
GOPP Sets the OPP on/off
==================================================

Table of Contents