69
4.4 Remote Communication Protocol
Command Description
ADDRess set the address of the machine
ADDRess? return the address of the machine
BEEP
set beep on(1) or off(0)
CLR clear protect status
CURRent set current
CURRent? return current setting
ERRor? return error message
IOUT? current readback
ISET
set current
ISET? return current setting
LOCK set rotary and keypad lock on(1) or off(0)
MODEL? return model name
OCP set current protect to off(0) or on(1)
OISET set overcurrent protect level
OISET? return overcurrent value
OPP set power protect to off(0) or on(1)
OPSET set overpower protect level
OPSET? return overpower value
OUT set output on(1) or off(0)
OVP set voltage protect to off(0) or on(1)
OVSET set overvoltage protect level
OVSET? return overvoltage value
STATUS? return status of the machine
VERsion? return version number
VOLTage set voltage
VOLTage? return voltage setting
VOUT? voltage readback
VSET Set up output voltage
VSET? return voltage setting