85
4.7 Multi-Unit Programming Commands
The multi-unit programming commands used by the power supply
include a carriage return (CR) character for termination of all ASCII strings.
For all configuration commands (except for commands listed under
Synchronous Control Commands section), the instrument will return a
string “OK” to indicate command sent successfully. If an error
occurs, it will return an error. See the “Error! Reference source not
found.” section for details.
4.7.1 System Control Commands
This set of commands is used to select the instrument (based on their
address) to control and to obtain/set its system settings.
C
ommand Description
==================================================
CADR Selects the address, which can be 1 to 30, of the power
supply to access and control.
CCLS Clear status
CRST Reset command. Brings the power supply to a
known state
CIDN? Returns the power supply model identification
CREV? Returns the firmware version
CSN? Returns the serial number
CST? Returns the device status
CCLR? Clear protect
==================================================
CADR
Note:
This command must be used first prior to any other