94
GRST
Description:
Resets all the power supplies connected in the
chain to a known state.
Syntax:
GRST
GCLS
Description:
Clears the status of all the power supplies
connected in the chain.
Syntax:
GCLS
GCLR
Description:
Clears the protection flag/trip of all the power
supplies connected in the chain.
Syntax:
GCLR
GPV
Description:
Configures/Queries the VSET voltage setting of all
the power supplies connected in the chain.
Example: GPV 150.68
Sets all the power supplies’ VSET voltage setting
to 150.68 V.
GPC
Description:
Configures/Queries the ISET current setting of all
the power supplies connected in the chain.
Example: GPC 3.123
Sets all the power supplies’ ISET current setting to