91
value of the selected power supply.
Example: COV 170.000
Sets the selected power supply’s OVP value to
170.000V.
COV?
Queries the selected power supply’s OVP value.
COVP
Description:
Configures/Queries the overvoltage protection state
of the selected power supply.
Example: COVP ON
Sets the selected power supply’s OVP state to ON.
COVP?
Queries the selected power supply’s state.
COC
Description:
Configures/Queries the overcurrent protection
value of the selected power supply.
Example: COC 3.000
Sets the selected power supply’s OCP value to
3.000 A.
COV?
Queries the selected power supply’s OCP value.
COCP
Description:
Configures/Queries the overcurrent protection state