37
that are connected to the Master. Therefore, in order to correctly configure the
correctly, user must set up the Slaves
before
To set a XLN3640/XLN6024/XLN8018/XLN10014 to slave mode, press
the Master is set.
,
, and
in the main screen to enter the series/parallel
setting option. And then select the parallel mode by turning the knob (SCPI
command is “PS:MODE PARALLEL”) and then press
to confirm. It
will continue to the next line for the MASTER/SLAVE selection. Turning the
knob to select SLAVE A (SCPI command is “PS:TYPE SLAVEA”) for the
supply and press
to confirm the setting. Using the same procedure,
setup SLAVE B and C for another two (2) supplies as shown below.
L
LL
=
=
L
L
L
To set the master unit, press
,
, and
in the main screen
to enter the series/parallel setting option. And then use the knob to select the
parallel mode (SCPI command is “PS:MODE PARALLEL”) and press
to confirm. It will continue to the next line for the MASTER/SLAVE selection.
Use knob again to select MASTER (SCPI command is “PS:TYPE MASTER”)
and then press
to confirm. After it is confirmed as the Master the
XLN3640/XLN6024/XLN8018/XLN10014 will start searching for all Slaves,
as shown below:
= LL L
=
F L
...
L
L
If wiring is correct, screen will appear as:
L
= LL L
=
:
L
L
F