142 en | Points D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
P## Swinger Bypass
Use the P## Swinger Bypass parameter to allow the control panel to bypass automatically a
point that reports two or more alarm or trouble events within the same arm cycle. The
maximum number of faults allowed on a point is set in the Swinger Count prompt (refer to
Section Swinger Count, page 177).
The control panel reports a Swinger Bypass when the Swinger Count is reached and P##
Report Bypass at Occurrence is set to Yes. If the point has a partial count (less than the
Swinger Count number of events during an hour), the count is reset to zero.
P## Report Bypass at Occurrence
Send a Command Bypass Report as soon as a user bypasses the point from the keypad.
Enable this option for all Bypassable 24-hour points. You can also report a bypassed point at
the time the area is armed. Refer to Section P## Defer Bypass Report, page 142.
P## Defer Bypass Report
Use this option to prevent P## Type (0 to F) points that are bypassed by the user (COMMAND
BYPASS) from occurring until the area is armed. When the area is armed, the bypassed points
NOTICE!
Programming Bypassable as Yes for Cross Points can cause missed Cross- Point alarms. For
example, if Points 1 and 2 were programmed as Cross Points and Point 1 was Bypassed or
Force Armed, Point 2 cannot generate an Alarm Cross Point Event. Point 2 can; however,
generate an Unverified or Alarm Event depending on how the point was faulted. Be careful
when using this feature with Cross Point applications.
Default: Refer to the program record sheet
Selection: Yes or No
Yes Enable Swinger Bypass for this point.
No Disable Swinger Bypass for this point.
NOTICE!
To meet UL requirements, set this parameter to No.
NOTICE!
P## Bypassable does not need to be programmed as Yes for swinger bypass to work.
NOTICE!
A Swinger Shunted point returns to the system if P## Bypass Returnable? is Yes. If not, return
the point to the system through manual unbypass or [COMMAND][0][0]. Refer to P## Bypass
Returnable in the program entry guide for additional information.
Default: Refer to the program record sheet
Selection: Yes or No
Yes Send a Command Bypass Report when the point is bypassed.
No Do not send a Command Bypass Report when the point is bypassed.
Default: Refer to the program record sheet
Selection: Yes or No
Yes Send a Point Bypass Report with the Closing Report instead of a
Command Bypass Report when a user bypasses the point.
No Do not defer Bypass Reports.