D9412GV4/D7412GV4/D7212GV4 Points | en 153
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
CMD9 Relay
This entry selects a relay (73 to 80 for the D9412GV4 or 9 to 16 for the D7412GV4 and
D7212GV4) when COMMAND 9 is initiated (refer to Section P### Relay Codes/Relays,
page 148 for relay number association).
CMD9 Point Text
Enter alphabetic characters A to Z in capital letters.
Enter up to sixteen characters of text to describe the point. This point text appears at keypads
(if the point is programmed as visible) and sent to the D6500 or D6600 when transmitting in
Modem IIIa
2
format (if it is a reporting point).
Default: 0
Selection: 0 to 8
NOTICE!
COMMAND 9 does not activate the Summary Fire Alarm relay.
Default: COMMAND 9
Selection: Up to sixteen alphanumeric characters