D9412GV4/D7412GV4/D7212GV4 Panel and Area Wide Parameters | en 81
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
CC# Area Assign
Enter the area number where you are installing this keypad or keypads with this address and
the same DIP switch settings.
CC# Scope
This program item is used to define the areas affected when an arming command is executed
on this keypad, the areas this keypad can view, and the areas to which this keypad can move.
CC# A1 (through A#) in Scope
NOTICE!
Reboot the system to enable a D1260 Series Keypad.
To reboot the system, close and open the reset switch, labeled “S1 RESET,” located in the
upper right corner of the control panel.
Default: 1
Selection: 1 to 32 on D9412GV4
1 to 8 on D7412GV4
1 to 4 on D7212GV4
Default: No Keypad (Panel Wide for keypads 1 and 8)
Selection: Panel Wide, Custom, No Keypad, Area, and Account
Panel Wide A panel-wide keypad can view information and perform Arming and
Disarming functions for all areas in the control panel. A panel-wide
keypad can cross account boundaries. This is normally used with a
master area.
Account An Account keypad can view information, and perform Arming and
Disarming functions for all areas with the same A# Account Number, in
Area Parameters. This is normally used for an associate area.
Area An area keypad is restricted to viewing information and Arming or
Disarming functions for the area to which it is assigned.
Custom A custom keypad shows information and allows arming and disarming
for specific areas you select. (This option is not available through
Keypad Programming.)
No Keypad No keypad installed at this address. CALL FOR SERVICE display shows,
indicating the control panel is not polling this address.
NOTICE!
In applications where keypads include more than one area, active alarms in remote areas must
be acknowledged before arming or disarming the local area.
NOTICE!
The following prompt is visible only when you program CC## Scope to Custom. If you change
the keypad scope selection to Custom from Panel Wide, Account, or Area, the settings from
the previous CC# Scope selection become the default settings for the custom parameters in
CC# A1 [through A#] in Scope. Before exiting from a custom program, check each area and
ensure that it is enabled and disabled correctly.
Default: None (All for Keypads 1 and 8)
Selection: Yes or No
Yes Include this area in the scope of this keypad.
No Do not include this area in the scope of this keypad.