94 en | Panel and Area Wide Parameters D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
Master Arm Delay
Use this arming function to master arm disarmed areas. If enabled, the following arming
choices are available to the user with this authority.
Master Arm Instant
Use this arming function to master arm instant areas that are disarmed. Entry and exit delays
are not provided with this arming function. This causes a Perimeter and Interior Delay point to
act as an Instant point.
For SIA CP-01 Compliance
Perimeter Instant
Instant arms all perimeter points with point response that starts an instant alarm (refer to P##
Pt Response in Section 5.2 Point Responses, page 132) in the area where the keypad is
assigned. Entry and exit delays are not provided with this arming function. This function
causes a Perimeter Delay point to act as a Perimeter Instant point.
For SIA CP-01 Compliance
NOTICE!
Refer to Section 3.12.6 Authority Level Selections, page 102 for a detailed description of the
functions on the following pages. These parameters determine only if the authority level
functions are passcode protected.
Default: P
Selection: -, E, or P
P Passcode: Required for all users with Master Arm Delay enabled for
their authority level.
E Enable: A user does not need a passcode to use [COMMAND][1].
- Disable Master Arm Delay cannot be accessed in the function menu or
started with a command even if this function is enabled for the user’s
authority level.
Function No. Function Name Alternate Keystroke
2 Master Arm Delay [COMMAND][1]
Default: - (Disabled)
Selection: -, E, or P
Function No. Function Name Alternate Keystroke
3 Master Arm Instant [COMMAND][1][1]
NOTICE!
This feature is not allowed to be used with SIA CP-01 compliant installations.
Default: - (Disabled)
Selection: -, E, or P
Function No. Function Name Alternate Keystroke
4 Perimeter Instant Arm [COMMAND][2]
NOTICE!
This feature is not allowed in SIA CP-01 compliant installations.