163
5.13 Error Codes 5.13 Error Codes
Nyon, Intuvia, Purion
error code
in DiagnosticTool
error code
in display
Error description, repair
0x4C002B
0x4C002C
0x4C002D
0x4C002E
–
Internal memory error. Print diagnostic report, clear error code, update
software, restart system. If the error persists, replace on-board computer.
0x4C002F
0x4C0030
–
Internal pressure sensor error. Print diagnostic report, clear error code,
update software, restart system. If the error persists, replace on-board
computer.
0x4C0031 –
Internal temperature sensor error. Print diagnostic report, clear error
code, update software, restart system. If the error persists, replace
on-board computer.
0x4C0032 –
External power supply too high. Print diagnostic report, clear error code,
update software, restart system. If the error persists, replace on-board
computer.
0x4C0033 –
External power supply too low. Print diagnostic report, clear error code,
update software, restart system. If the error persists, replace on-board
computer.
0x4C0034
0x4C0035
–
Internal light sensor error. Print diagnostic report, clear error code,
update software, restart system. If the error persists, replace on-board
computer.
0x4C0036
0x4C0037
0x4C0038
0x4C0039
–
Internal memory error. Print diagnostic report, clear error code, update
software, restart system. If the error persists, replace on-board computer.
0x4C003A –
Internal remote control error. Print diagnostic report, clear error code,
update software, restart system. If the error persists, replace on-board
computer.
0x4C003B –
Internal on-board computer error. Print diagnostic report, clear error code,
update software, restart system. If the error persists, replace on-board
computer.
0x4C003C
0x4C003D
0x4C003E
–
Internal software error. Print diagnostic report, clear error code, update
software, restart system. If the error persists, replace on-board computer.
HMI (model years 2011/2012)
error code
in DiagnosticTool
error code
in display
Error description, repair
0x00 00 02
0x00 00 03
0x00 00 04
0x00 00 05
0x00 00 06
0x00 00 07
002 Check whether keys are blocked.
0x00 00 08 003
Communication problem between HMI and other components.
Check wiring and contacts.
0x00 00 11 001 Internal error in the HMI.
5
SERVICE