Item/Parameter No. Function Setting range
004 Minimum pause time 10 to 9,999 msec
■ DIALTONE
Bit switch
Bit No. Function 1 0
Bit 0 - - -
Bit 1 Cadence pattern check No Yes
Bit 2 Signal frequency Changed Not changed
Bit 3 - - -
Bit 4 Judgment of intermittent signal Start from valid ON signal Start from either valid ON
signal or OFF signal
Bit 5 - - -
Bit 6 Signal form Continuous Intermittent
Bit 7 Signal detection Yes No
Numeric value parameter
Parameter No. Function Setting range
001 T0 timer 0 to 9,999 (x10 msec)
002 T1 timer 0 to 9,999 (x10 msec)
003 T2 timer 0 to 9,999 (x10 msec)
004 T3 timer 0 to 9,999 (x10 msec)
005 T4 timer 0 to 9,999 (x10 msec)
006 Signal detection table 0 to 16
007 Signal detection level 0 to 7
008 Number of signal frequency 0 to 9,999
■ 2ND DLTN (2nd DIAL TONE)
Not used
■ BUSTONE0 (BUSY TONE 0)
Bit switch
Bit No. Function 1 0
Bit 0 - - -
Bit 1 - - -
Bit 2 - - -
Bit 3 - - -
Bit 4 - - -
Bit 5 - - -
Bit 6 - - -
Bit 7 Signal detection Yes No
Numeric value parameter
Not used
■ BUSTONE1 (BUSY TONE 1)
Bit switch
Bit No. Function 1 0
Bit 0 - - -