COPIER (Service mode for printer) > FUNCTION (Operation / inspection mode) > SPLMAN
SPL10250 Setting at Drum Cartridge error
Detail To set whether to display the error screen when a non-genuine drum cartridge or a drum cartridge
which memory cannot be read is installed.
Adj/Set/Operate Method
Enter the setting value, and then press OK or Apply key.
Caution
When set to "1", the error screen is displayed and printing is paused.
Display/Adj/Set Range
0/1
0: Do not display
1: Display
Default Value
1
SPL12612 Set auto sleep setting display
Detail To set whether to display the auto sleep time screen.
Adj/Set/Operate Method
Enter the setting value, and then press OK or Apply key.
Caution
When set to "0", auto sleep time cannot be set and auto sleep is disabled (OFF).
Display/Adj/Set Range
0/1
0: Do not display
1: Display
Default Value
1
Additional Functions
Mode
Menu > Timer Settings> Auto Sleep Time
SPL71110 Set pseudo CI DUTY
Detail To set the pseudo CI DUTY
Adj/Set/Operate Method
Enter the setting value, and then press OK or Apply key.
Display/Adj/Set Range
0 to 9999
Supplement/Memo
Fax model only
SPL78148 Mode to execute new B&W processing of PCL
Detail To make the density gradation characteristics of halftone the same as those of conventional B&W
machines.
Use Case
When setting the density gradation characteristics in line with those of conventional machines
- Resolution: Further increase the density in high-density areas
- Gradation: Uniformly change the gradation from a low-density area to a high-density area
- Color Tone: Further reduce the density in low-density areas.
Adj/Set/Operate Method
Enter the setting value, and then press OK or Apply key.
Display/Adj/Set Range
0/1
0: Enable
1: Disable
Default Value
1
Supplement/Memo
PCL mounted model only
OPTION (Specification setting mode)
■ BODY
COPIER (Service mode for printer) > OPTION (Specification setting mode) > BODY
DFDST-L2 Dust detect level threshold value: ADF
Detail To set the threshold value of dust detection level at ADF stream reading (detection after completion
of job)
Adj/Set/Operate Method
Enter the setting value, and then press OK or Apply key.
Display/Adj/Set Range
0 to 255 (0: OFF)
Default Value
100