COPIER (Service mode for printer) > FUNCTION (Operation / inspection mode) > SPLMAN
LEFT-DUP-CST Adjust left edge margin 2nd of 2-sided
Detail As the value is changed by 1, the margin on the left edge of paper is changed by 0.1 mm.
+: Left edge margin becomes larger. (An image moves to the right.)
-: Left edge margin becomes smaller. (An image moves to the left.)
Use Case
When adjusting the left edge registration margin of the 2nd side of the 2-sided printing at the time
of pickup from the Pickup Tray.
Adj/Set/Operate Method
Enter the setting value, and then press OK or Apply key.
Display/Adj/Set Range
50 to 150
Unit
0.1 mm
Default Value
92
SPL14159 USB device ID setting
Detail To set whether to fix the USB device ID to "000000000000".
This machine tries to install drivers every time PC is connected. When the USB device ID is fixed,
the machine consider the same PC is connected, so there will be no need to install the drivers
many times.
Adj/Set/Operate Method
Enter the setting value, and then press OK or Apply key.
Display/Adj/Set Range
0/1
0: Do not fix
1: Fix
Default Value
0
SPL27354 PC-less update, RMDS env setting
Detail To set the PC-less update and RMDS environment setting.
Adj/Set/Operate Method
Enter the setting value, and then press OK or Apply key.
Display/Adj/Set Range
0 to 5
0: Production environment/Release environment
1: Production environment/Staging environment
2: Maintenance environment 1/Release environment
3: Maintenance environment 1/Staging environment
4: Maintenance environment 2/Release environment
5: Maintenance environment 2/Staging environment
Default Value
0
SPL32620 PC-less update setting
Detail To set switching to enable/disable PC-less update
Use Case
When changing the setting of PC-less update
Adj/Set/Operate Method
Enter the setting value, and then press OK or Apply key.
Display/Adj/Set Range
0/1
0: Disable
1: Enable
Default Value
1
SPL10249 Setting at Toner Cartridge error
Detail To set whether to display the error screen when a non-genuine toner cartridge or a toner cartridge
which memory cannot be read is installed.
Adj/Set/Operate Method
Enter the setting value, and then press OK or Apply key.
Caution
When set to "1", the error screen is displayed and printing is paused.
Display/Adj/Set Range
0/1
0: Do not display
1: Display
Default Value
1