Appendix
263
A275 Image buffer for upload overflowed
[warning]
Memory card warning
M201 Memory card is write-protected
[warning]
M203 Not enough space on memory card
[warning]
M204 Invalid file removed [warning]
M205 Checking management information file
[warning]
M206 Invalid management information
removed [warning]
Notification log
System notification
S001 System started [info]
S002 System settings changed [info]
S010 Event service started [info]
S011 Event service shut down [info]
S012 External device service started [info]
S013 External device service shut down
[info]
S014 Timer service started [info]
S015 Timer service shut down [info]
Description buffer queue is full (A275)
Meaning Image buffer for upload overflowed.
Countermeasure Make adjustments to reduce the
number of event occurrences. Also
adjust the video quality, video size and
frame rate for upload.
Description Readonly filesystem (M201)
Meaning A write-protected memory card is
inserted.
Description There is not available space (M203)
Meaning Insufficient memory card capacity.
Description Invalid file %1 was removed. (M204)
%1 Name of removed file
Meaning An invalid file was removed.
Description %1 checking management file (M205)
%1 Start | Finish
Meaning The memory card may have been
removed without being unmounted.
Start/finish checking management
information file.
Description Invalid db information(%1)(%2) was
removed(M206)
%1 Name of management information file
containing invalid information
%2 ID of invalid information
Meaning Invalid management information was
removed.
Description starting paramd (S001)
Meaning Parameter management module
started.
Description Updated system settings. (S002)
Meaning Settings not requiring rebooting were
changed.
Description starting event (S010)
Meaning The event service was started.
Description shutdown event (S011)
Meaning The event service was shut down.
Description starting extio (S012)
Meaning The external device input/output
service was started.
Description shutdown extio (S013)
Meaning The external device input/output
service was shut down.
Description starting timer (S014)
Meaning The timer service was started.
Description shutdown timer (S015)
Meaning The timer service was shut down.