158 Technical data CG Drives & Automation 01-5980-01r2
1) Normal duty: Start current = 3 x I
n_soft
, Start time = 15 s (Size 1) or 30 s (Size 2-4), 10 starts/hour,
Heavy duty: Start current = 5 x I
n_soft
, Start time = 15 s (Size 1) or 30 s (Size 2-4), 10 starts/hour.
2) Fuse data for Semi-conductor fuses, see Table 48.
3) H1=Height of enclosure, H2= Total height.
Table 44 Technical data for Emotron TSA52/69-070 to -100.
Emotron TSA Size 2 model:
TSA52/69-070 TSA52/69-085 TSA52/69-100
Duty
(1)
Normal Heavy Normal Heavy Normal Heavy
Rated current I
n_soft
[A] 70 42 85 51 100 60
Motor size P
n_mot
400 V [kW] - TSA52-### 37 22 45 22 55 30
Motor size P
n_mot
460 V [hp] - TSA52-### 50 30 60 40 75 40
Motor size P
n_mot
525 V [kW] - TSA52-### 45 22 55 30 75 37
Motor size P
n_mot
575 V [hp] - TSA69-### 60 40 75 50 100 60
Motor size P
n_mot
690 V [kW] - TSA69-### 55 37 75 45 90 55
Recommended load fuses [A]
(2)
100 100 125 125 160 160
Total power loss for TSA unit at rated motor
power, in bypass mode [W]
28 21 33 23 38 26
Total average power loss for TSA unit if
10 starts/hour [W]
102 95 114 105 133 122
Dimensions H1/H2 x W x D [mm (in)]
(3)
246/340 x 126 x 188 (9.7/13.4 x 5 x 7.4)
Mounting position Vertical/Horizontal
Weight [kg (lb)] 5.7 (12.6)
Busbar for cable connection [mm (in)] 15 x 2 (0.59 x 0.08), M6 connection.
Possible to use either Cu or Al cables.
Cooling system Fan
Protection class IP20
UL short circuit rating 10 kA
Table 45 Technical data for Emotron TSA52/69-140 to -200.
Emotron TSA Size 3 model:
TSA52/69-140 TSA52/69-170 TSA52/69-200
Duty
(1)
Normal Heavy Normal Heavy Normal Heavy
Rated current I
n_soft
[A] 140 84 170 102 200 120
Motor size P
n_mot
400 V [kW] - TSA52-### 75 45 90 55 110 55
Motor size P
n_mot
460 V [hp] - TSA52-### 100 60 125 75 150 100
Motor size P
n_mot
525 V [kW] - TSA52-### 90 55 110 75 132 75
Motor size P
n_mot
575 V [hp] - TSA69-### 125 75 150 100 200 125
Motor size P
n_mot
690 V [kW] - TSA69-### 132 75 160 90 200 110
Recommended load fuses [A]
(2)
200 200 224 224 250 250
Total power loss for TSA unit at rated motor
power, in bypass mode [W]
43 30 52 34 61 38
Total average power loss for TSA unit if
10 starts/hour [W]
167 155 204 188 233 212
Dimensions H1/H2 x W x D [mm (in)]
(3)
285/380 x 196 x 235 (11.2/14.9 x 7.7 x 9.3)
Mounting position Vertical/Horizontal
Weight [kg (lb)] 13 (28.7)
Busbar for cable connection [mm (in)] 20 x 5 (0.8 x 0.20), M10 connection.
Possible to use either Cu or Al cables.
Cooling system Fan
Protection class IP20
UL short circuit rating 18 kA