EasyManua.ls Logo

Chroma 63800 Series - Setup Subsystem

Chroma 63800 Series
198 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programmable AC/DC Electronic Load 63800 Series Operation & Programming Manual
8-24
Description: This command sets the RS-232 stop bit length of the electronic load.
Setting Syntax : SYSTem:COMMunicate:SERial:SBIT
Setting Parameter : 1 | 2
Query Syntax : SYSTem:COMMunicate:SERial:SBIT?
Response Parameter: 1 | 2
Example : SYST:COMM:SER:SBIT 1
SYSTem:COMMunicate:SERial:PARity
Description: This command sets the RS-232 parity type of the electronic load.
Setting Syntax : SYSTem:COMMunicate:SERial:PARity
Setting Parameter : NONE|ODD|EVEN
Query Syntax : SYSTem:COMMunicate:SERial:PARity?
Response Parameter: NONE|ODD|EVEN
Example : SYST:COMM:SER:PAR NONE
8.6.4.3 Setup Subsystem
SYSTem
:SETup
:MODE Set AC / DC mode for 63800
:CFPF
:MODE Set CF only / PF only / ALL mode
:PRIOrity Set the CF / PF priority for Both mode
SYSTem:SETup:MODE
Description: It sets the mode of electronic load as AC load mode or DC load mode.
Setting Syntax : SYSTem:SETup:MODE
Setting Parameter : <NR1>, 0 | AC, 1 | DC
Query Syntax : SYSTem:SETup:MODE?
Response Parameter: AC | DC
SYSTem:SETup:CFPF:MODE
Description: It sets the modes of CF/PF/ALL. This command is only operating in AC CC/CP
modes. When this command sets as 0, it indicates the system enter to CF only mode. When
this command sets as 1, it indicates the system enter to PF only mode. When this command
sets as 2, the system decides the margin setting value of CF PF according to the setting of
priority.
Setting Syntax : SYSTem:SETup:CFPF:MODE
Setting Parameter : 0 | CF, 1 | PF, 2 | ALL
Query Syntax : SYSTem:SETup:CFPF:MODE?
Response Parameter: 0 | 1 | 2
SYSTem:SETup:CFPF:PRIOrity
Description: It sets the priority of CF PF. This command is only operating in AC CC/CP modes.
When this command sets as 0, it indicates CF is high priority. When this command sets as 1,
it indicates PF is high priority.
Setting Syntax : SYSTem:SETup:CFPF:PRIOrity
Setting Parameter : 0 | CF, 1 | PF
Query Syntax : SYSTem:SETup:CFPF:PRIOrity?
Response Parameter: CF| PF

Table of Contents