Remote Operation
8-25
8.6.5 Parallel Subsystem
PAR
:STAT
PAR:STAT
Description: It returns the status of the current parallel mode. When the response parameter
is 0, it indicates parallel mode error. When the response parameter is 1, it indicates single
phase parallel. When the response parameter is 2, it indicates three phases parallel.
Query Syntax : PAR:STAT?
Response Parameter: <NR1>, 0 | 1 | 2
Example : PAR:STAT?
8.6.6 PHASE Subsystem
PHASe
:SEL
PHASe:SEL
Description: It decides LOAD, MEAS and FETC subsystem commands are belong to three
phases balance (ALL) or three phases unbalance (phase A, B, C) setting. (This command is
only for three phases parallel used.)
Setting Syntax : PHASe:SEL
Setting Parameter : ALL, A,B,C
Query Syntax : PHAS:SEL?
Response Parameter: ALL | A | B | C
Example : PHAS:SEL ALL