Programmable AC/DC Electronic Load 63800 Series Operation & Programming Manual
Example : MEAS:CURR:CRES?
MEASure[:SCALar]:CURRent:PEAK:NEGative?
FETCh[:SCALar]:CURRent:PEAK:NEGative?
Description: Return the negative peak current measured at the input of electronic load.
Query Syntax : MEASure[:SCALar]:CURRent:PEAK:NEGative?
FETCh[:SCALar]:CURRent:PEAK:NEGative?
Response Parameter: <NR2>
Example : MEAS:CURR:PEAK:NEG?
MEASure[:SCALar]:CURRent:PEAK:POSitive?
FETCh[:SCALar]:CURRent:PEAK:POSitive?
Description: Return the positive peak current measured at the input of electronic load.
Query Syntax : MEASure[:SCALar]:CURRent:PEAK:POSitive?
FETCh[:SCALar]:CURRent:PEAK:POSitive?
Response Parameter: <NR2>
Example : MEAS:CURR:PEAK:POS?
8.6.2.2 Frequency Measurement
MEASure | FETCh
[:SCALar]
:FREQuency? Return the output frequency
MEASure[:SCALar]:FREQuency?
FETCh[:SCALar]:FREQuency?
Description: Return the output frequency in Hertz.
Query Syntax : MEASure[:SCALar]:FREQuency?
FETCh[:SCALar]:FREQuency?
Response Parameter: <NR2>
Example : MEAS:FREQ?
8.6.2.3 Power Measurement
MEASure | FETCh
[:SCALar]
:POWer
:[REAL] ? Return real power
:AMPLitude
:MAX? Return peak power
:APParent? Return VA
:PFACtor? Return power factor
:REACtive? Return the reactive power
MEASure[:SCALar]:POWer[:REAL]?
FETCh[:SCALar]:POWer[:REAL]?
Description: Return the true power in Watts (W).
Query Syntax : MEASure[:SCALar]:POWer[:REAL]?
FETCh[:SCALar]:POWer[:REAL]?
Response Parameter : <NR2>