Local Operation
2. Press 1 , then press ENTER to enter SETUP. (The display please refer 3.6.1 BOTH
mode.)
3. Move the direction key ( ▲, ▼ ) to “1-5. CF/PF SETTING”.
4. Press the direction key ( ◄, ► ) or rotate the rotary knob to choose “CF”, then press
ENTER. (The display please refer 3.6.1 BOTH mode.)
5. Then press CC to back to main page.
Users can press the arrow key to select the setting parameters on the LCD display, including
current RMS value, CF, and I
p
(max).
V
=
0
. 0
0
P
=
0
. 0
0
I =
0
. 0
0
S
=
0
. 0
0
The procedures of setting I
set
= 5.100, CF = 1.51 and I
p
(max) = 20.2, are described as below:
1. Move the cursor to the command line of “I
set
=”.
2. Press 5 , . , 1 then press ENTER to change the value to “5.100”.
3. Move the cursor by pressing ( ◄, ► ) to the command line of “CF=”.
4. Press 1 , . , 5 , 1 then press ENTER to change the value to “1.510”.