10-6 Common procedures
6200 Packet-Optical Platform Installation, Commissioning, and Testing Procedures
Release 1.1 009-6200-201 Draft Issue 1
Copyright
©
2014 Ciena
®
Corporation September 2014
Procedure 10-3
Inserting and Ejecting the power supply unit-APU290
Use this procedure to insert or eject the power supply unit-APU290 on base
chassis of an 6200 network element.
Note: The 6200 network element supports APU290 in redundant
configuration only. A combination of AC and DC power supply source is
not supported on the base chassis.
Prerequisites
Make sure that a manual Phillips star screwdriver is available.
Action
Step Action
Inserting the power supply unit-APU290
1 Determine your next step.
CAUTION
Risk of equipment damage
To avoid damage to the PSUs, remove the PSU cables before
jack-out of PSUs.
CAUTION
Risk of equipment damage
Electrostatic discharge can damage electrostatic sensitive
devices. Use antistatic protection to avoid damaging circuit
packs.
CAUTION
Risk of circuit pack damage
Do not force any circuit pack all the way back of its slot if it
resists insertion. Before you install any of the circuit packs,
make sure you understand the detailed procedure for insertion
of circuit packs.
If you want to Then go to
insert the power supply unit-APU290 step 2
remove the power supply unit-APU290 step 9