EasyManua.ls Logo

Claas DOMINATOR 130 - 17 Changing the Fuel Filter PERKINS 1006-6 T

Claas DOMINATOR 130
390 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
290 00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09
13 Maintenance
13.5 Engine
67089
86235
13.5.17 Changing the fuel filter
PERKINS 1006-6T
Observe the general warnings at the beginning of
the "Maintenance" chapter.
Observe the information provided in the operator's
manual of the engine manufacturer.
Close the shut-off tap of the fuel system.
Drain fuel from filter.
- Hold a suitable container for the remaining fuel
in the sight glass (4) beneath the hose.
- Slacken off the drain plug.
- Collect escaping liquid in a suitable container.
- Tighten drain plug.
Unscrew filter (1) with sight glass (4).
Clean the inside of the filter head.
Apply some oil to the new seal and screw new
filter (1) with sight glass (4) to the filter head at
right angles and centred.
Open the shut-off tap of the fuel system.
Environment!
Lubricants and fuels end up in the
environment.
Environmental pollution.
Lubricants and fuels must be collected
and stored in suitable containers and dis-
posed of in a way that is harmless to the
environment and in accordance with
existing anti-pollution regulations.
WARNING:
Soiling of fuel system.
Machine damage.
Make sure surroundings are clean.
Use suitable and clean tools.
Ensure that no dirt can enter the fuel
system.
29
29344
1
4
WARNING:
Use of unpermissible spare parts or
lubricants.
Machine damage or increased wear.
Spare parts and lubricants must at least
comply with the technical standards
required by the manufacturer of the
implement!
The use of genuine CLAAS spare parts
and lubricants is recommended.

Table of Contents