00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09 295
13 Maintenance
13.5 Engine
67089
Unscrew filter (2).
Apply some oil to the new seal and screw on new
filter (2) until the filter seal touches the filter head.
Tighten the filter by hand.
Top up oil at position (A).
Check the oil level.
Top up oil if required.
Screw on the lid (1) at position (A).
Start the diesel engine.
Let the diesel engine run at lower no-load speed
for about 10 seconds.
Check the oil level.
Top up oil if required.
38745
13.5.20 Adjusting the diesel engine valves
Observe the information provided in the operator's
manual of the engine manufacturer.
86455
13.5.21 Checking the radiator coolant level
Observe the general warnings at the beginning of
the "Maintenance" chapter.
Let diesel engine cool down.
Ensure that the drain cock of the cooling system is
closed.
38
27295
39
29342
40
29343
2
A
1
2
A
1
2
A
1
WARNING:
Use of unpermissible spare parts or
lubricants.
Machine damage or increased wear.
Spare parts and lubricants must at least
comply with the technical standards
required by the manufacturer of the
implement!
The use of genuine CLAAS spare parts
and lubricants is recommended.
Caution!
Machine operation with unpermitted or pol-
luted lubricants.
Machine damage.
Ensure a clean environment.
Use suitable and clean tools.
Use permitted lubricants.
Lubricants must be free of pollution.