00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09 347
13 Maintenance
13.10 Electric system / Electronics
67089
13.10 Electric system / Electronics
85765
13.10.1 Checking the battery electrolyte level
Observe the general warnings at the beginning of
the "Maintenance" chapter.
The battery can be accessed from the discharge and
cooling system compartment.
Unscrew all covers (1).
Check electrolyte level.
The electrolyte level must be about 10 mm above
the inside plates.
Top up distilled water if required.
Fit all covers (1).
Fit safety device.
Close the cover.
Environment!
Handling of used batteries.
Environmental pollution.
Dispose of old batteries in a way that is
harmless to the environment and in
accordance with existing anti-pollution
regulations.
121
23496
1
Danger!
Incorrect handling of batteries.
Death or serious injury.
Be careful with battery gases, they are
highly explosive.
Avoid sparks and naked flames in the
vicinity of a battery!
Remove the covers (vent caps) when
recharging the battery to prevent the
accumulation of highly explosive gases.
Be careful when handling battery acids,
they are caustic.