00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09 351
13 Maintenance
13.11 Cab / Operator's platform
67089
– Check the moisture saturation at the
receiver/dryer (1).
The moisture saturation of the receiver/dryer is
exceeded when the blue ball in the sight glass has
turned pink, or the orange ball has become colourless.
– If necessary, change refrigerant.
– If required, replace filter receiver drier (1).
86839
13.11.7 Changing the air conditioner
refrigerant
– Observe the general warnings at the beginning of
the "Maintenance" chapter.
Danger!
Refrigerant.
Death or serious injury.
– Only have authorised and qualified work-
shops carry out work on air conditioning
systems.
– Never get in contact with refrigerants!
– Wear safety gloves and safety goggles.
– Do not weld any components of the refrig-
erant circuit and or in the immediate
vicinity of any parts of the refrigerant
circuit.
– Maximum ambient temperature for refrig-
erant is 80 °C.
128
23858
1
Danger!
Refrigerant.
Death or serious injury.
– Only have authorised and qualified work-
shops carry out work on air conditioning
systems.
– Never get in contact with refrigerants!
– Wear safety gloves and safety goggles.
– Do not weld any components of the refrig-
erant circuit and or in the immediate
vicinity of any parts of the refrigerant
circuit.
– Maximum ambient temperature for refrig-
erant is 80 °C.

Table of Contents