246 00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09
12 Faults and remedies
12.2 Cab / Operator's platform
67088
Compressor too loud. • Compressor bearings damaged.
- Have the compressor repaired or replaced.
For this, the system has to be discharged
using the correct recovery equipment and
then recharged.
• Oil level in compressor too low (indicated by
external leakage).
- Have repair work carried out by a specialist
workshop.
Check oil level in compressor only with sys-
tem drained.
For this, system has to be discharged using
the correct recovery equipment.
Moisture in cab.
Water dripping from air louvres.
• Water drain hoses clogged or not properly
routed.
- Check water drain hoses for free passage.
If necessary, blow out hoses with com-
pressed air.
Malfunction Possible cause and remedy