246 00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09
12 Faults and remedies
12.2 Cab / Operator's platform
67088
Compressor too loud. Compressor bearings damaged.
- Have the compressor repaired or replaced.
For this, the system has to be discharged
using the correct recovery equipment and
then recharged.
Oil level in compressor too low (indicated by
external leakage).
- Have repair work carried out by a specialist
workshop.
Check oil level in compressor only with sys-
tem drained.
For this, system has to be discharged using
the correct recovery equipment.
Moisture in cab.
Water dripping from air louvres.
Water drain hoses clogged or not properly
routed.
- Check water drain hoses for free passage.
If necessary, blow out hoses with com-
pressed air.
Malfunction Possible cause and remedy