EasyManua.ls Logo

Claas DOMINATOR 150 - 13.9 Hydraulic system

Claas DOMINATOR 150
390 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
340 00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09
13 Maintenance
13.9 Hydraulic system
67089
13.9 Hydraulic system
86485
13.9.1 Checking the hydraulic system oil level
Park the machine on level ground.
Lower the feeder as far as possible.
Lower the reel all the way.
Swing in unloading auger tube.
Observe the general warnings at the beginning of
the "Maintenance" chapter.
Read the oil level on the gauge rod (1).
The oil must not be higher than the FULL mark (maxi-
mum) and must not drop below the SAFE mark
(minimum) on the oil dipstick.
If necessary, refill with oil at (A).
86487
13.9.2 Changing the hydraulic system oil / oil
filter / fresh air filter element
DOMINATOR 150 / 140
Park the machine on level ground.
Lower the feeder as far as possible.
Lower the reel all the way.
Swing in unloading auger tube.
Caution!
Machine operation with unpermitted or pol-
luted lubricants.
Machine damage.
Ensure a clean environment.
Use suitable and clean tools.
Use permitted lubricants.
Lubricants must be free of pollution.
111
DOMINATOR 150 / 140
23377
112
DOMINATOR 130
23382
1
A
A
1

Table of Contents