00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09 349
13 Maintenance
13.11 Cab / Operator's platform
67089
86814
13.11.3 Cleaning the cab roof units
Observe the general warnings at the beginning of
the "Maintenance" chapter.
Open cab roof (1).
Unscrew cover from cab.
Blow out evaporator (3) and hot-water radiator (4)
with compressed air (5 bar max.).
Replace damaged seals (1) beneath the cover.
Bolt down cover from cab.
Close cab roof (1).
Note!
Dirty units will have reduced heating and cool-
ing capacity.
Uneconomic use of machine.
Observe the specified maintenance
intervals.
Clean the units more frequently when
working in very dusty conditions.
WARNING:
Cleaning of sensitive components with exces-
sive levels of compressed air or other cleaning
means.
Component damage.
Never direct the compressed air jet
directly to sensitive components such as
cooling fins or filter elements.
Never use a steam jet cleaner for
cleaning.
124
23854
4
3
2
Designation
2Fan
3 Evaporator
4Radiator