EasyManua.ls Logo

Claas DOMINATOR 150 - Page 271

Claas DOMINATOR 150
390 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09 271
13 Maintenance
13.3 Maintenance schedule
67089
Hydraulic system
Hydraulic system Oil level check • • •
Hydraulic system Oil / oil filter / Fresh
air filter element
change
•
Electrical / electronic equipment
Battery acid level check ••
Cab / operator's platform
Cab air filter clean •
Cab air filter change • •
Cab recirculation air filter clean ••
Cab roof-mounted units clean • •
Air conditioner put into
operation
•
Air conditioner refrigerant moisture
saturation
check
• •
Air conditioner refrigerant change (only through authorised
workshop)
••
Intake
Feed rake conveyor retainers clean •
Feeder chains adjust • •
Slip clutch feeder chain adjust •
Rasp plate on feed rake conveyor check •
Threshing mechanism
Concave adjust • •
Threshing mechanism clean •
Stone trap clean • •
Separation
Straw walker clean •
Deflector curtain check •
Performance monitor sensors clean • •
Cleaning unit
Performance monitor sensors clean • •
Fan clean •
Setting the fan speed gauge •
Stepped preparation floors clean •
Sieves clean •
Maintenance operations Service intervals in working hours
Before the harvest
After the
first
Daily
Every
Once a year or every 500
every 2 years
As required
After the harvest
10 100 50 100 250

Table of Contents