Software
Copyright © 2015 Coda Octopus Products Ltd
91
F180R MOTION Sensor User and Reference Guide
The Calibration field displays the current calibration state of the F180R System. The system's
outputs should not be used until the F180R System calibration is complete. This field can be
one of five states:
Indicates that no Data Source
is selected.
The system is unable to
determine the calibration
state. This is usually due to an
invalid Connection.
The system is been instructed
to Start a Calibration (via new
settings uploaded from the
MOTION Settings Wizard) but
has yet to reach the required
specification.
A user-requested calibration
is not in progress and the
F180R System has not reached
a calibrated state.
The system has reached a
calibrated state and the
outputs can now be used.
To display the Calibration Status dialog go to Live Tab - Calibration Status. This dialog displays
the current calibration status, the duration of the current calibration and the current Heading
and Attitude Accuracies.
Double clicking the Calibration LED will also display the Calibration Status dialog.