soft error limit. settings and retest
(see Chapter 9, "Jumper and
1703 - 04 Previously exceeded maximum Switch Settings").
hard error limit. 2. Replace the fixed disk drive
signal and power cables and
1703 - 05 Failed to reset controller. retest.
3. Replace the fixed disk drive
1703 - 06 Fatal error while reading. and retest.
4. Replace the system board and
1703 - 07 Fatal error while writing. retest.
1703 - 08 Failed compare of write/
read buffers.
1703 - 40 Cylinder 0 error.
1703 - 55 Cylinder 1 error.
1703 - 63 Failed soft error rate.
1703 - 65 Exceeded maximum bad sector
per track.
1703 - 67 Failed to write long.
------------------------------------------------------------------------------
Error
Code Error Description Recommended Action
------------------------------------------------------------------------------
1703 - 68 Failed to read long. The following steps apply to error
codes 1700 - xx through 1717 - 73:
1703 - 70 Failed translate mode.
1. Check the system board jumper
1703 - 71 Failed nontranslated mode. settings and retest
(see Chapter 9, "Jumper and
1703 - 72 Exceeded maximum bad track Switch Settings").
limit. 2. Replace the fixed disk drive
signal and power cables and
1703 - 73 Previously exceeded maximum retest.
bad track limit. 3. Replace the fixed disk drive
and retest.
1704 - xx Fixed Disk Drive Random Seek 4. Replace the system board and
Test. retest.
1704 - 01 Exceeded maximum soft error
limit.
1704 - 02 Exceeded maximum hard error
limit.
1704 - 03 Previously exceeded maximum
soft error limit.
1704 - 04 Previously exceeded maximum
hard error limit.
1704 - 05 Failed to reset controller.