1210 - 09 Modem exceeded maximum
redial limit.
1210 - 10 Line quality prevented
remote connection.
1210 - 11 Modem timed out waiting
for remote connection.
==============================================================================
Table 6-11. Fixed Disk Drive Error Codes (17xx - xx Range)
==============================================================================
Error
Code Error Description Recommended Action
------------------------------------------------------------------------------
1700 - xx Fixed Disk Drive ID Test The following steps apply to error
codes 1700 - xx through 1717 - 73:
1700 - 05 Failed to reset controller
1. Check the system board jumper
1700 - 09 Failed to format a track settings and retest (see
Chapter 9, "Jumper and Switch
1700 - 41 Failed to ID fixed disk drive Settings").
(drive not ready). 2. Replace the fixed disk drive
signal and power cables and
1700 - 42 Recalibrate fixed disk drive retest.
failed. 3. Replace the fixed disk drive
and retest.
1700 - 45 Failed to get fixed disk 4. Replace the system board and
drive parameters from ROM. retest.
1700 - 46 Invalid fixed disk drive
parameters found in ROM.
1700 - 66 Failed to initialize fixed
disk drive parameter.
1700 - 69 Failed to read drive size
from controller.
1700 - 70 Failed translate mode.
1700 - 71 Failed nontranslated mode.
------------------------------------------------------------------------------
Error
Code Error Description Recommended Action
------------------------------------------------------------------------------
1701 - xx Fixed Disk Format Test The following steps apply to error
codes 1700 - xx through 1717 - 73:
1701 - 05 Failed to reset controller
1. Check the system board jumper
1701 - 09 Failed to format a cylinder settings and retest (see
Chapter 9, "Jumper and Switch
1701 - 42 Recalibrate fixed disk drive Settings").
failed. 2. Replace the fixed disk drive
signal and power cables and
1701 - 58 Failed to write sector retest.
buffer. 3. Replace the fixed disk drive