Commander SE Advanced User Guide 101
Issue Number: 4
The delay time that is required for the loss of communications to cause a trip.
0 = Disabled
1 = Little (LSB 1st)
0 = Big (MSB 1st)
This parameter selects the order of bytes transmitted/received for cyclic data words.
* Parameter
e.g. 11.28 = 11.28
0 = Disabled
* Parameter
e.g. 11.28 = 11.28
0 = Disabled
Cleared once defaults are loaded.
Indicates the software sub version of the fieldbus module software.
15.07 Trip delay time
Ú
0 ~ 9999
Ö
0msRWUni
15.08 Endianism
Ú
0 or 1
Ö
0 RW Bit
15.09~
15.10
Unused parameters
15.11~
15.12
Cyclic IN mappings
Ú
0 ~ 96.99
Ö
0*RWUni
0-9 0-9 0-9 0-9
XX
YY
15.13~
15.20
Unused parameters
15.21~
15.22
Cyclic OUT mappings
Ú
0 ~ 96.99
Ö
0*RWUni
0-9 0-9 0-9 0-9
XX
YY
15.23~
15.29
Unused parameters
15.30 Load option defaults
Ú
0 or 1
Ö
0 RW Bit
15.31~
15.49
Unused parameters
15.50 Software version zz (Reserved)
Ú
0 ~ 99
Ö
RO Uni

Table of Contents

Other manuals for Control Techniques COMMANDER SE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Control Techniques COMMANDER SE and is the answer not in the manual?

Control Techniques COMMANDER SE Specifications

General IconGeneral
BrandControl Techniques
ModelCOMMANDER SE
CategoryController
LanguageEnglish

Related product manuals