8 Commander SE Advanced User Guide
Issue Number: 4
Procedure
1. Fit insulation boot over cable insulation.
2. Strip approximately 25mm of the insulation and peel foil shield back over cable insulation
3. Fit the Ferrule flush with the cable insulation and crimp.
4. Remove cable wrap and fan out cables in the required order. Fit the cable spacer to within 2.5mm of the ferrule.
5. Cut cable to 6mm above cable spacer and fit into RJ45 ensuring all cables are in the correct channels and crimp.
6. Cut back foil shield flush with RJ45 connector and slide up insulation boot over the RJ45 connector.

Table of Contents