DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
223
Restrictions
None.
Example
To display the CFM configuration:
DWS-3160-24PC:admin#show cfm
Command: show cfm
CFM State: Enabled
MD Index MD Name Level
---------- ---------------------- -----
1 MD 0
DWS-3160-24PC:admin#show cfm md MD
Command: show cfm md MD
MD Index : 1
MD Name : MD
MD Level : 0
MIP Creation: None
SenderID TLV: None
MA Index MA Name VID
---------- ---------------------- ----
1 MA 1
DWS-3160-24PC:admin#show cfm md MD ma MA
Command: show cfm md MD ma MA
MA Index : 1
MA Name : MA
MA VID : 1
MIP Creation: Defer
CCM Interval: 10 seconds
SenderID TLV: Defer
MEPID List : 1
MEPID Direction Port Name MAC Address
----- --------- ----- ----------- -----------------
1 Inward 1 MEP 00-11-22-33-45-77
DWS-3160-24PC:admin#show cfm mepname MEP
Command: show cfm mepname MEP
Name : MEP
MEPID : 1
Port : 1
Direction : Inward
CFM Port Status : Disabled