Web Operations 192
5.3.3.2 Configuring Alarm Input Settings
Select SETUP > EVENT > ALARM.
Step 1
The ALARM interface is displayed. See Figure 5-78.
Alarm setting Figure 5-78
Select alarm input type. Step 2
Local Alarm: The alarm signal detected by the alarm input port on the Device.
IPC Disconnect: The alarm signal is generated when the IP camera is
disconnected.
Select the Enable check box and the channel that you want to apply the tampering Step 3
detect function.
If Local Alarm is selected, select a channel from Channel 1 to Channel 7.
If IPC Disconnect is selected, select a channel from Channel 9 to Channel 12.
Configure the parameters. For details, see Table 5-30.
Step 4
Table 5-30 Alarm parameters description
Enter a customized alarm name.
Select the Overlay check box, the alarm name will display on the
channel window.
Enter event detection lasting time. The system records only one event
during this period.
If Local Alarm is selected, configure this parameter.
Normal Open: The alarm signal is disconnected normally. The alarm
is activated when alarm signal is closed.
Normal Close: The alarm signal is closed normally. The alarm is
canceled when alarm signal is disconnected.
If Local Alarm is selected, configure this parameter.
High: The alarm signal is 12V/24V voltage. Low: The alarm signal is
signal ground.