After the cover-area is configured, the real-time monitoring cannot be
performed to the covered area.
When Channel 1 to Channel 8 is selected, both Preview and Monitor check
boxes are displayed. When Channel 9 to Channel 12 is selected, only the
Monitor check box is available.
You can configure total 4 covered blocks for each channel.
1. Next to the Cover-Area, select the Preview check box or the Monitor
box.
The "1, 2, 3, 4" buttons are displayed, which represent the number of
blocks.
Preview: The covered area is visible when output to VGA monitor
or small screen, but invisible when output to web or during
recording.
Monitor: The covered area is invisible when output to VGA monitor
or small screen, but visible when output to web or during recording.
2. Click the buttons to select blocks, and then click Setup.
3. Drag the block to the area that you want to cover and adjust the size of
the block. Right-click on the screen to return to Overlay interface. You
can also change the size and position of each block.
4. Click Save.
Select the corresponding check box to display the system time or channel
title on the channel window in the live view screen.
1. Select the Monitor check box for Time Display, Channel Display,
License No., and GPS Display. The corresponding content will display
on the channel window.
2. Click Setup.
3. Drag the title to a proper position, and then right-click on the screen to
return to Overlay interface.
4. Click Save.
The configured titles are displayed on the windows of live view screen.