Enter/Exit Programming Mode 1D Symbologies
106
Gryphon™ GPS4400
Code 39 Set Length 1
This feature specifies one of the bar code lengths for Code 39 Length Control.
Length 1 is the minimum label length if in Variable Length Mode, or the first
fixed length if in Fixed Length Mode. Length includes the bar code’s data
characters only. The length can be set from 0 to 50 characters.
Table 3 provides examples for setting Length 1. See page 241 for detailed
instructions on setting this feature.
Table 3. Code 39 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 Characters 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 39 LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Code 39 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again
at the beginning.
CANCEL
DEFAULT
02 = Length 1 is 2 Characters