1D Symbologies Enter/Exit Programming Mode
Product Reference Guide
163
MSI Check Character Calculation
Enables/Disables calculation and verification of an optional MSI check char-
acter.
$CMSCC00(CR)
MSI Check Character Calculation = Disable
$CMSCC01(CR)
MSI Check Character Calculation = Enable Mod10
DEFAULT
$CMSCC02(CR)
MSI Check Character Calculation = Enable Mod11/10
$CMSCC03(CR)
MSI Check Character Calculation = Enable Mod10/10
MSI Check Character Transmission
Enables/disables transmission of an MSI check character.
$CMSCT00(CR)
MSI Check Character Transmission = Disable
$CMSCT01(CR)
MSI Check Character Transmission = Enable
DEFAULT