Extended System-Level Command Functions
44 Class Series 2 Programmer’s Manual
Configuration Set Commands
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Menu Item (or Number)
(if available)
Command
Equivalent
Alignment Length
AL
0 – 999 1/100 inch (18) N/A
Backup After Print
BA
Y, N
Y = Enabled,
N = Disabled
System Settings N/A
Backup Delay
BD
0 – 255 1/50 second System Settings N/A
Backup Label
BL
0, 3, 4
0 = Disabled,
3 = Active Low,
4 = Active High
Printer Options N/A
Backup (Reverse) Speed
BS or bS
alpha character
Model specific
ranges; see
Appendix L.
Print Control
pa
British Pound
BP
Y, N
Y = Enabled,
N = Disabled
N/A N/A
Buzzer Enable
BZ
Y, N
Y = Enabled,
N = Disabled
System Settings N/A
(continued)

Table of Contents

Other manuals for Datamax E-Class Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax E-Class Mark II and is the answer not in the manual?

Datamax E-Class Mark II Specifications

General IconGeneral
Resolution203 dpi (8 dots/mm) or 300 dpi (12 dots/mm)
Operating Temperature40°F to 95°F (4°C to 35°C)
Storage Temperature-40°F to 140°F (-40°C to 60°C)
Print MethodDirect Thermal / Thermal Transfer
Max Print Speed6 inches per second (ips)
Memory8 MB DRAM
InterfaceSerial, Parallel, USB
Media TypeLabels, Tags, Receipts
Media Width0.75" (19 mm) to 4.65" (118 mm)
Media Thickness0.0025 to 0.008 inches (0.0635 to 0.2032 mm)
Power Requirements100-240 VAC, 50-60 Hz

Related product manuals