EasyManuals Logo

Dell PowerEdge C6220 II Hardware Owner's Manual

Dell PowerEdge C6220 II
345 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #251 background imageLoading...
Page #251 background image
Installing System Components | 251
3 Align the cooling-fan cage with the locating pins on the chassis and
place it into the chassis until it’s firmly seated in place. See Figure 3-68.
4 Connect the fan’s power cable to the connector on the power
distribution board 1. See Figure 3-68.
You must route these cables properly through the ties to prevent them
from being pinched or crimped.
5 Close the system. See Closing the Systemon page 247.
6 Reconnect the system to its electrical outlet and turn on the system,
including any attached peripherals.
Power Distribution Boards
Removing a Power Distribution Board
CAUTION: Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came with
the product.
NOTE: This system has two power distribution boards. The procedure to remove
and install both the power distribution boards is similar. To access the power
distribution board 2 at the bottom, remove the power distribution board at the top.
1 It is recommended to turn off the system, including any attached
peripherals, and disconnect the system from its electrical outlet.
2 Open the system. See Opening the Systemon page 246.
3 Remove the power supply. See Removing and Installing a Power
Supplyon page 160.
4 Disconnect all the cables from the power distribution board 1. See
Figure 3-75.
Note the routing of the cable on the chassis as you remove them from
the system. You must route these cables properly when you replace
them to prevent the cables from being pinched or crimped.

Table of Contents

Other manuals for Dell PowerEdge C6220 II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge C6220 II and is the answer not in the manual?

Dell PowerEdge C6220 II Specifications

General IconGeneral
Form Factor2U Rack
ProcessorIntel Xeon E5-2600 v2 series
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi
MemoryUp to 512GB DDR3 per node
StorageUp to 24 x 2.5" hot-plug SAS, SATA, or SSD drives
NetworkDual 1GbE, optional 10GbE
ManagementDell Remote Access Controller (iDRAC7) with Lifecycle Controller
Number of ProcessorsUp to 2 per node (4 total in 2U chassis)
Power SupplyRedundant hot-plug power supplies