314 | Troubleshooting Your System
Troubleshooting System Memory
CAUTION: Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came with
the product.
NOTE: Invalid memory configurations can cause your system to halt at startup
without video output. See System Memoryon page 230 and verify that your
memory configuration complies with all applicable guidelines.
1 If the system is not operational, turn off the system and attached
peripherals, and unplug the system from the power source. Wait at
least 10 seconds and then reconnect the system to power.
2 Turn on the system and attached peripherals and note the messages on
the screen.
Go to step 10 if an error message appears indicating a fault with a
specific memory module.
3 Enter the System Setup program and check the system memory
settings.
See Main Screen on page 76. Make any changes to the memory
settings, if needed.
If the memory settings match the installed memory but a problem is
still indicated, go to step 10.
4 Turn off the system and attached peripherals, and disconnect the
system from the electrical outlet.
5 Remove the system-board assembly. See Removing a System-Board
Assemblyon page 163.
6 Reseat the memory modules in their sockets. See Installing the
Memory Moduleson page 234.
7 Install the system-board assembly. See Installing a System-Board
Assemblyon page 164.

Table of Contents

Other manuals for Dell PowerEdge C6220 II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge C6220 II and is the answer not in the manual?

Dell PowerEdge C6220 II Specifications

General IconGeneral
Form Factor2U Rack
ProcessorIntel Xeon E5-2600 v2 series
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi
MemoryUp to 512GB DDR3 per node
StorageUp to 24 x 2.5" hot-plug SAS, SATA, or SSD drives
NetworkDual 1GbE, optional 10GbE
ManagementDell Remote Access Controller (iDRAC7) with Lifecycle Controller
Number of ProcessorsUp to 2 per node (4 total in 2U chassis)
Power SupplyRedundant hot-plug power supplies