38 | About Your System
System Event Log
Processor Error
Message: “Processor Sensor, IERR error, Processor 1”
Byte
Field
Value
Description
1 NetFunLun 10h
2 Platform Event Command 02h
3 Generator ID 01h Generated by BIOS
4 Event Message Format Version 04h Event Message Format
Revision. 04h for this
specification
5 Sensor Type 07h Processor
6 Sensor Number 04h Processor Sensor Number
(depends on platform)
7 Event Direction Event Type 6Fh Bit 7: 0 = Assert Event
Bit 6: 0 = Event Type Code
8 Event Data1 AXh 00h: IERR
01h: Thermal Trip
02h: FRB1/BIST Failure
03h: FRB2/Hang in POST
Failure
04h: FBR3/Processer
Startup/Initialization Failure
0Ah: Processor Automatically
Throttled
9 Event Data2 XXh 00h: Processor1
01h: Processor2
02h: Processor3
04h: Processor4
10 Event Data3 FFh FFh: Not Present

Table of Contents

Other manuals for Dell PowerEdge C6220 II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge C6220 II and is the answer not in the manual?

Dell PowerEdge C6220 II Specifications

General IconGeneral
Form Factor2U Rack
ProcessorIntel Xeon E5-2600 v2 series
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi
MemoryUp to 512GB DDR3 per node
StorageUp to 24 x 2.5" hot-plug SAS, SATA, or SSD drives
NetworkDual 1GbE, optional 10GbE
ManagementDell Remote Access Controller (iDRAC7) with Lifecycle Controller
Number of ProcessorsUp to 2 per node (4 total in 2U chassis)
Power SupplyRedundant hot-plug power supplies