Installing System Components | 303
3 Replace the screw that secures the sensor board to the hard drive cage.
See Figure 3-106.
4 Connect the sensor board cable to the sensor board. See Figure 3-108.
5 Replace the hard drive cage into the chassis. See Figure 3-93.
6 Replace the screws that secure the hard-drive cage to the chassis. See
Figure 3-92.
7 Connect all the cables to the backplane. See Figure 3-91 for 2.5-inch
hard drives.
You must route these cables properly on the chassis to prevent them
from being pinched or crimped.
8 Connect the front panel cables to the power distribution board. See
Figure 3-105 or Figure 3-108.
You must route these cables properly on the chassis to prevent them
from being pinched or crimped.
9 Close the system. See Closing the Systemon page 247.
10 Replace the hard drives. See Installing a Hard Drive into a Hard-Drive
Carrieron page 159.
11 Reconnect the system to its electrical outlet and turn on the system,
including any attached peripherals.
Cable Routing for Sensor Board and Front Panel for 2.5” Hard Drive
System
1 Connect the Y-shaped cable for the sensor board and front panel 2 to
the connector on the power distribution board 1, and connect the other
two ends of the cable to the connectors on the sensor board and the
front panel 2 respectively.
2 Connect the front panel cable to the connector on the power
distribution board 1, and connect the other end of the cable to the
connector on the front panel 1.

Table of Contents

Other manuals for Dell PowerEdge C6220 II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge C6220 II and is the answer not in the manual?

Dell PowerEdge C6220 II Specifications

General IconGeneral
Form Factor2U Rack
ProcessorIntel Xeon E5-2600 v2 series
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi
MemoryUp to 512GB DDR3 per node
StorageUp to 24 x 2.5" hot-plug SAS, SATA, or SSD drives
NetworkDual 1GbE, optional 10GbE
ManagementDell Remote Access Controller (iDRAC7) with Lifecycle Controller
Number of ProcessorsUp to 2 per node (4 total in 2U chassis)
Power SupplyRedundant hot-plug power supplies

Related product manuals